Industrial Construction

Industrial Construction

The aim of this tool is for customers to quickly perform an early feasibility check on their development concept to assess project viability. Upon submission, one of our experienced estimators will firm up this initial estimate on request, so please feel free to contact us with any queries.

Please select

State *

Area *

Please select

Full height metal clad

Up to 9m springing height, 150th thick floor, 4 tonne racking post-load, 3 tonne fork, standard lighting (excluding sprinklers)

View Example

2.1m high precast & metal cladding above

Up to 9m springing height, 150th thick floor, 4 tonne racking post-load, 3 tonne fork, standard lighting (excluding sprinklers)

View Example

Full height precast panels

Up to 9m springing height, 150th thick floor, 4 tonne racking post-load, 3 tonne fork, standard lighting (excluding sprinklers)

View Example
Please select

Full height metal clad

Up to 9m springing height, 150th thick floor, 4 tonne racking post-load, 3 tonne fork, standard lighting (excluding sprinklers)

View Example

2.1m high precast & metal cladding above

Up to 9m springing height, 150th thick floor, 4 tonne racking post-load, 3 tonne fork, standard lighting (excluding sprinklers)

View Example

Full height precast panels

Up to 9m springing height, 150th thick floor, 4 tonne racking post-load, 3 tonne fork, standard lighting (excluding sprinklers)

View Example
Please select

Chiller (Including +2c to +4C Refrigeration)

Up to 10m ceiling height, PIR insulated panel type, smoke detection, standard lighting (excluding sprinklers)

View Example

Freezer (Including -25C Refrigeration)

Up to 10m ceiling height, floor insul., PIR insulated panel type, glycol heating, smoke detection, standard lighting (excluding sprinklers)

View Example

Annex (Including +4C Refrigeration)

Up to 8m ceiling height, PIR insulated panel type, manual tilt doors, dock igloos, dock equipment, standard lighting, smoke detection (excluding sprinklers)

View Example

Plant Room/Battery Re-Charge

6m springing height, 150mm thick floor, precast concrete walls, standard lighting (excluding sprinklers)

Please select

6m cantilevered canopy

Excluding sprinklers

View Example

8m cantilevered canopy

Excluding sprinklers

View Example

10m cantilevered canopy

Excluding sprinklers

View Example

12m cantilevered canopy

Excluding sprinklers

View Example
Please select

Single Level: Premium

Office façade incorporating precast panels, alucobond, full height glazing and sunscreens, feature entry canopy,carpet, HVAC, reception, male and female amenities with full height wall tiling, lunchroom, meeting room, IT room, executive offices, balance open plan layout (excluding sprinklers).

View Example

Double Level: Premium

Office façade incorporating precast panels, alucobond, full height glazing and sunscreens, feature entry canopy,carpet, HVAC, reception, two male and female amenities with full height wall tiling, lunchroom, meeting room, IT room, executive offices, balance open plan layout (excluding sprinklers).

View Example

Single Level: Economy

Office facade incorporating predominately precast panels with integrated windows and full height glazed entry and feature entry canopy, carpet, HVAC, reception, male and female amenities core, meeting room, executive offices, balance open plan (excluding sprinklers)

View Example

Double Level: Economy

Office facade incorporating predominately precast panels with integrated windows and full height glazed entry and feature entry canopy, carpet, HVAC, reception, two male and female amenities core, meeting room, executive offices, balance open plan (excluding sprinklers)

View Example

Showroom

Glazed façade incorporating alucobond feature elements including entry canopy, carpet, HVAC, amenities core, balance open plan, (excluding sprinklers)

View Example

Basement Car Park

Basement excavation, bored piers and retaining walls, associated ramps, concrete slab and mech vent (excluding sprinklers)

View Example
Please select

Heavy Duty Concrete - suitable for unlimited truck traffic

175mm reinforced concrete paving including earthwork, stormwater drainage, kerbing and lights

View Example

Medium Duty Concrete – suitable for limited truck traffic

150mm reinforced concrete paving including earthwork, stormwater drainage, kerbing and lights

View Example

Asphalt car park paving

Includes earthwork, stormwater drainage, kerbing and lights.
Please indicate parking space required in M2 OR no.

View Example

90 tonne axle-load container fork and 60 tonne max containers stacked load

Post tension concrete paving including earthwork, stormwater drainage, kerbing and lights

90 tonne axle-load Container Fork and 60 tonne max Containers stacked load

Extra heavy duty bitumen paving including earthwork, stormwater drainage, kerbing and lights

View Example

Crushed Rock Apron

200mm crushed rock including earthwork and stormwater drainage

Fire Access Track

150mm crushed rock track including earthwork and stormwater drainage

 

Please select

Australian Standard Fire Sprinkler Protection

Excluding Tank/Pumps

View Example

Fire Sprinkler Tanks and Pumps

 

View Example

50mm Roof Insulation Blanket

 

View Example

Evaporative Cooling to Factory

 

Office Partitioning

3 x 3.5m office with glazed fronts per 10sqm office

View Example

Passenger Lift including shaft and builders works

Dock Levellers

Including recess dock, retaining walls, Armco rail, roller shutter door and dock leveller (excluding canopy)

View Example

Overhead Crane

Additional structure to base steel for 10 tonne overhead crane load (excluding crane)

View Example

Overhead Crane

10 tonne overhead crane (6m hook height) including runway beams/rail, downshop wiring and service platform

Automatic Gates

View Example

Boom gate

4.5m boom arm, limit switch and vehicle safety loop/detector

View Example

Outdoor area

Including 1.5m high precast concrete screen wall, paving and sails shade

View Example

Gatehouse, 6.6m x 4.2m x 3m high

View Example

Weighbridge Builder's Work

Excludes Weighbridge equipment

View Example

Truck Wash Builder's Work

Including bunding, 210m2 canopy, and associated hydraulics

View Example
Please select

Rainwater Harvesting Tank

45,000 litre above ground (includes mains back-up, reticulation to toilets and irrigation)

View Example

"Smart Lighting" management system to warehouse

PE cells and PLC controls, 100% - 50% diagonal control pattern

View Example

Further Information

Any other specific information regarding the building site?

Any project information which may be relevant and useful for Vaughans?

How did you hear about Vaughans?

Contact details

Many thanks for your submission. We'll contact you shortly.